Precision-control-systems 930 Manual do Utilizador Página 12

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 29
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 11
Model 930 ControlIR
TM
Instruction Manual Operating Instructions
Research, Inc. Page 8 of 25
Remote Setpoint Input
Figure 3-3 Control Connections
This feature allows the power level of the system to be controlled from a remote
location or device. This is accomplished by applying a 0-5 VDC or 0-20 mA signal
input from a remote source. This feature is not available when the ‘Temperature
Controller’ option is installed. If this feature is desired use the following procedure:
1. For a 0-5 VDC input, connect the source to TB 100 pins 16+ and 17-.
2. For a 0-20 mA input, connect the source to TB 100 pins 16+ and 17-. Also
install a 250 ohm resistor across terminals TB 100 16+ and 17-.
Vista de página 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 28 29

Comentários a estes Manuais

Sem comentários